{"product_id":"30w-explosion-proof-jelly-jar-light-4050lm-c1d1","title":"30W Explosion-Proof Jelly Jar Light, 4050LM, 5000K, C1D1","description":"\n\u003c!-- ================= TRUST BAR ================= --\u003e\n\u003cp style=\"font-weight:bold;color:#689C38;\"\u003e✔ 30W | 4,050 Lumens | 5000K | Class I Division 1 | 0–10V Dimmable\u003c\/p\u003e\n\n\u003c!-- ================= HERO ================= --\u003e\n\u003ch2\u003e30W Explosion-Proof Jelly Jar Light – Hazardous-Location Lighting\u003c\/h2\u003e\n\u003cp\u003eThe TANLITE 30W explosion-proof jelly jar light delivers 4,050 lumens of bright 5000K illumination for demanding hazardous environments. Its compact IP66-rated construction is designed for industrial areas where flammable gases, vapors, combustible dust, fibers, moisture or corrosion may be present.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e30W power with 4,050-lumen output\u003c\/li\u003e\n\u003cli\u003eHigh efficacy of 135 lumens per watt\u003c\/li\u003e\n\u003cli\u003e5000K daylight for clear task visibility\u003c\/li\u003e\n\u003cli\u003eAC 100–277V universal input\u003c\/li\u003e\n\u003cli\u003e0–10V dimmable lighting control\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\u003c!-- ================= APPLICATION ================= --\u003e\n\u003ch2\u003eDesigned for Hazardous Industrial Locations\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOil refineries and petrochemical plants\u003c\/li\u003e\n\u003cli\u003eChemical processing facilities\u003c\/li\u003e\n\u003cli\u003ePower generation stations\u003c\/li\u003e\n\u003cli\u003eGrain handling and milling plants\u003c\/li\u003e\n\u003cli\u003ePaint storage and manufacturing areas\u003c\/li\u003e\n\u003cli\u003eIndustrial warehouses and loading zones\u003c\/li\u003e\n\u003cli\u003eWastewater treatment facilities\u003c\/li\u003e\n\u003cli\u003eMarine and offshore environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\u003c!-- ================= HAZARDOUS RATINGS ================= --\u003e\n\u003ch2\u003eHazardous-Location Rated Construction\u003c\/h2\u003e\n\u003cp\u003eDesigned for classified areas requiring a rugged and dependable compact LED fixture. Hazardous-location ratings include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eClass I, Division 1, Groups B, C and D\u003c\/li\u003e\n\u003cli\u003eClass I, Division 2, Groups A, B, C and D\u003c\/li\u003e\n\u003cli\u003eClass II, Division 1, Groups E, F and G\u003c\/li\u003e\n\u003cli\u003eClass II, Division 2, Groups F and G\u003c\/li\u003e\n\u003cli\u003eClass III hazardous locations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\u003c!-- ================= PERFORMANCE ================= --\u003e\n\u003ch2\u003eEfficient, Wide-Area Industrial Illumination\u003c\/h2\u003e\n\u003cp\u003eThe fixture produces 4,050 lumens using only 30 watts. Its 120° beam distributes light across entrances, corridors, stairways, equipment areas and compact industrial workspaces.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e135 lm\/W energy efficiency\u003c\/li\u003e\n\u003cli\u003e120° wide beam angle\u003c\/li\u003e\n\u003cli\u003e5000K daylight output\u003c\/li\u003e\n\u003cli\u003eCompact jelly jar design\u003c\/li\u003e\n\u003cli\u003eReduced energy and maintenance requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\u003c!-- ================= DURABILITY ================= --\u003e\n\u003ch2\u003eIP66 Protection for Demanding Environments\u003c\/h2\u003e\n\u003cp\u003eThe sealed heavy-duty aluminum housing and protective glass help shield internal components from dust, water and demanding industrial operating conditions.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIP66 weather-resistant and dust-tight design\u003c\/li\u003e\n\u003cli\u003eCorrosion-resistant aluminum housing\u003c\/li\u003e\n\u003cli\u003eProtective glass lens\u003c\/li\u003e\n\u003cli\u003eDesigned for vibration-prone industrial locations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\u003c!-- ================= CONTROL ================= --\u003e\n\u003ch2\u003e0–10V Dimmable 100–277V Operation\u003c\/h2\u003e\n\u003cp\u003eThe universal AC 100–277V input supports common commercial and industrial power systems. Integrated 0–10V dimming leads allow connection to a compatible control system. A separate 0–10V dimmer or control circuit is required and is not included.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003c!-- ================= CERTIFICATION ================= --\u003e\n\u003ch2\u003eETL Certified for Hazardous-Location Applications\u003c\/h2\u003e\n\u003cp\u003eThe fixture carries an ETL certification and is evaluated to applicable requirements including UL 1598, UL 1598A, UL 844 and UL 924. ABS suitability supports applicable marine and offshore projects.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003c!-- ================= FEATURES ================= --\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e 30W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLumen Output:\u003c\/strong\u003e 4,050 lm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficacy:\u003c\/strong\u003e 135 lm\/W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor Temperature:\u003c\/strong\u003e 5000K\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e AC 100–277V, 50\/60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimming:\u003c\/strong\u003e 0–10V dimmable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBeam Angle:\u003c\/strong\u003e 120°\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e IP66\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 5-year limited warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\u003c!-- ================= SPEC ================= --\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;font-weight:bold;\"\u003eWattage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e30W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;font-weight:bold;\"\u003eLumen Output\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e4,050 lumens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;font-weight:bold;\"\u003eEfficacy\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e135 lm\/W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;font-weight:bold;\"\u003eCCT\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5000K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;font-weight:bold;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eAC 100–277V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;font-weight:bold;\"\u003eDimming\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e0–10V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;font-weight:bold;\"\u003eBeam Angle\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;font-weight:bold;\"\u003eIP Rating\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;font-weight:bold;\"\u003eHazardous Rating\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eClass I Div 1 \u0026amp; 2; Class II Div 1 \u0026amp; 2; Class III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;font-weight:bold;\"\u003eCertification\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eETL; UL 1598, UL 1598A, UL 844, UL 924; ABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;font-weight:bold;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e5 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003chr\u003e\n\u003c!-- ================= CTA ================= --\u003e\n\u003ch2\u003eNeed Help with a Hazardous-Location Project?\u003c\/h2\u003e\n\u003cp\u003eContact TANLITE for fixture selection, bulk pricing and commercial project support. Please provide the hazardous-location classification, voltage, mounting requirements and quantity.\u003c\/p\u003e","brand":"TANLITE","offers":[{"title":"Default Title","offer_id":42213639356505,"sku":"TL-EX-JJ-30W-120V-5000K","price":313.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1583\/1027\/files\/tanlite-30w-explosion-proof-jelly-jar-light-main_72842428-1c06-4244-bba0-92c60a72ba6b.jpg?v=1787910084","url":"https:\/\/tanlite.com\/products\/30w-explosion-proof-jelly-jar-light-4050lm-c1d1","provider":"TANLITE","version":"1.0","type":"link"}